Comparative Characteristics Of Linear Displacement Of Proximal Femoral Department Fragments In Transosseous Fixation. Saratov Journal of Medical Scientific Research
In the present research a comparison of two techniques of transosseous fixation of pertrochanteric fracture has been drawn. By way of example linear relocations of fragments have been measured in 8 biodummies (femurs of cows) in two groups through three series of loadings along the long axis of a fe...
Gespeichert in:
Veröffentlicht in: | Saratovskiĭ nauchno-medit͡s︡inskiĭ zhurnal 2009-09, Vol.5 (3), p.399-403 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | rus |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In the present research a comparison of two techniques of transosseous fixation of pertrochanteric fracture has been drawn. By way of example linear relocations of fragments have been measured in 8 biodummies (femurs of cows) in two groups through three series of loadings along the long axis of a femur with a step of 490 N from 980 up to 2940 N. The specific load in the range of 16,08±0,65 N/sm2 — 16,32±0,065 N/sm2 causes linear fragment dislocation within 0,13±0,016 mm — 0,08±0,03 mm. Compressive variant of osteosynthesis improves stability of biomechanical system "a bone-fixator" 3-4 times as much |
---|---|