Comparative Characteristics Of Linear Displacement Of Proximal Femoral Department Fragments In Transosseous Fixation. Saratov Journal of Medical Scientific Research

In the present research a comparison of two techniques of transosseous fixation of pertrochanteric fracture has been drawn. By way of example linear relocations of fragments have been measured in 8 biodummies (femurs of cows) in two groups through three series of loadings along the long axis of a fe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Saratovskiĭ nauchno-medit͡s︡inskiĭ zhurnal 2009-09, Vol.5 (3), p.399-403
Hauptverfasser: О A. Kauts, A.G. Rusanov, A.P. Barabash
Format: Artikel
Sprache:rus
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the present research a comparison of two techniques of transosseous fixation of pertrochanteric fracture has been drawn. By way of example linear relocations of fragments have been measured in 8 biodummies (femurs of cows) in two groups through three series of loadings along the long axis of a femur with a step of 490 N from 980 up to 2940 N. The specific load in the range of 16,08±0,65 N/sm2 — 16,32±0,065 N/sm2 causes linear fragment dislocation within 0,13±0,016 mm — 0,08±0,03 mm. Compressive variant of osteosynthesis improves stability of biomechanical system "a bone-fixator" 3-4 times as much
ISSN:1995-0039
2076-2518