Physical properties of soft contact lens multipurpose solutions commercially available in Ghana

To investigate the physical properties of commercially available multipurpose soft contact lens solutions in Ghana. pH (Kelilong ICL-099 pH meter, China), osmolality (OSMOMAT 3000, GONOTEC, Germany), surface tension (Sigma 700 Tensiometer, Sweden), and viscosity (CFOC-200 Viscometer, Cannon Company,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Heliyon 2024-06, Vol.10 (12), p.e32491, Article e32491
Hauptverfasser: Ilechie, Alex, Addo, Naa Adjeley, Aidoo, Elsie, Armah, Anthony, Faheem, Fateena, Achimah, Bismark A.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To investigate the physical properties of commercially available multipurpose soft contact lens solutions in Ghana. pH (Kelilong ICL-099 pH meter, China), osmolality (OSMOMAT 3000, GONOTEC, Germany), surface tension (Sigma 700 Tensiometer, Sweden), and viscosity (CFOC-200 Viscometer, Cannon Company, USA) of various soft contact lens multipurpose solutions (MPS) were measured in triplicates at room temperature. Viscosity measurements were also taken at 34 °C ocular surface temperature. The solutions examined were Opti-Free Replenish (OFR), Trufresh (TF), Avizor (AV), Freshlook (FL), and Refresh (RF). Several solutions were largely hypo-osmotic in the range of 108–231 mOsm/kg, the exception being Avizor, which had osmolality values that were closer to human tears (301 ± 0.58 mOsm/kg). The range of pH values of the solutions (6.33–8.24, mean (SD) = 7.53 ± 0.18) fell within the reported tolerable range for the ocular surface (6.20–9.00). Surface tension values ranged from 35.86 to 42.27 mNm with a mean of 38.49 ± 2.32 mNm. The average viscosity of most solutions at room temperature (25 °C) was 1.44 ± 0.49 cP with a range of 1.04–2.15 cP. Significantly lower values ranging from 0.79 to 1.58 cP were obtained at ocular surface temperature (34 °C), p = 0.0001). The physical properties of many of the solutions used as MPS in Ghana are markedly variable. Nevertheless, pH, surface tension, and viscosity fall within the acceptable limits of ocular physiological tolerance; except for osmolality, which majority were outside the reported tolerable range for the ocular surface. This information may partly explain the reason some patients exhibit strong preferences for certain care systems and should aid clinical decision-making when prescribing eye care systems to patients. •We evaluated the physical properties of multipurpose soft contact lens solutions in Ghana.•There were unique variations in the physical properties of the tested solutions.•Many solutions exhibited hypo-osmotic values outside the range for the ocular surface.•However, viscosity, pH, and surface tension were within acceptable eye ranges.•Findings offer evidence to guide patient preferences in prescribing eye care systems.
ISSN:2405-8440
2405-8440
DOI:10.1016/j.heliyon.2024.e32491