Introduction: Sufficient information is not available regarding the comparative accuracy of digital and conventional impression techniques at different depths for the fabrication of endocrown restorations. Thus, this study aimed to compare the marginal (M) and internal (I) adaptation of endocrowns a...
Gespeichert in:
Veröffentlicht in: | International journal of dentistry 2024-01, Vol.2024 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction: Sufficient information is not available regarding the comparative accuracy of digital and conventional impression techniques at different depths for the fabrication of endocrown restorations. Thus, this study aimed to compare the marginal (M) and internal (I) adaptation of endocrowns at different depths fabricated by the digital and conventional impression techniques.Materials and Methods: In this in vitro study, two endodontically treated molar teeth with 2- and 4-mm cavity depths were used for the fabrication of endocrowns. Conventional and digital impressions were made from each tooth 17 times. A total of 68 zirconia endocrowns were fabricated and seated, and their I and M adaptation was assessed by the silicone replica technique. Data were statistically analyzed.Results: The M and I gaps at 2- and 4-mm cavity depths were significantly smaller in the digital, than the conventional, impression technique (p |
---|---|