γ-radiolysis of boric acid-lithium hydroxide-ammonia coolant
In this study, the γ-radiolysis of boric acid-lithium hydroxide-ammonia coolant was investigated under different conditions, including boric acid concentration, absorbed dose, and absorbed dose rate. The concentrations of H2O2, NO2-, and NO3- were determined using UV-visible spectroscopy and ion chr...
Gespeichert in:
Veröffentlicht in: | Fu she yan jiu yu fu she gong yi xue bao 2023-06, Vol.41 (3), p.030201-030201 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | chi |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, the γ-radiolysis of boric acid-lithium hydroxide-ammonia coolant was investigated under different conditions, including boric acid concentration, absorbed dose, and absorbed dose rate. The concentrations of H2O2, NO2-, and NO3- were determined using UV-visible spectroscopy and ion chromatography. With an increase in boric acid concentration, the concentrations of H2O2 and NO2- in the coolant system did not change significantly within a pH range commonly used in pressurized water reactor operation. Specifically, the concentration of H2O2 varied from 9.28×10-5 to 1.07×10-4 mol/L, while that of NO2- changed from 0.9×10-5 to 1.5×10-5 mol/L. In contrast, the concentration of NO3- fluctuated significantly, ranging from 4×10-5 to 8×10-5 mol/L. With an increase in the absorbed dose (1-30 kGy), the equilibrium concentration of H2O2 and NO2- in boric acid-lithium hydroxide-ammonia system increased to 1.28×10-4 mol/L and 1.30×10-5 mol/L, respectively. Meanwhile, the concentration of NO3- did not change si |
---|---|
ISSN: | 1000-3436 |
DOI: | 10.11889/j.1000-3436.2023-0020 |