Simulation with a colour indicator to help reduce contamination during airway management in COVID-19 times: An experience from a tertiary centre in India
Background and Aims: The coronavirus disease 2019 (COVID-19) pandemic has initiated modified protocols for aerosol-generating procedures. A simulation study using dye was conducted to highlight contamination at intubation and extubation and to encourage adherence to the new COVID-19 protocol among a...
Gespeichert in:
Veröffentlicht in: | Indian journal of anaesthesia 2021-11, Vol.65 (11), p.820-829, Article 820 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background and Aims: The coronavirus disease 2019 (COVID-19) pandemic has initiated modified protocols for aerosol-generating procedures. A simulation study using dye was conducted to highlight contamination at intubation and extubation and to encourage adherence to the new COVID-19 protocol among anaesthesia personnel in our institution. Methods: A video demonstrating the new COVID-19 protocols was circulated in the Department of Anaesthesiology a week prior to the study. Thirty teams, each comprising an anaesthesia resident and a staff technician, were enroled. Each team was asked to demonstrate the steps of preparation, intubation and extubation on a mannequin in a COVID-19 scenario. Checklists were used to assess points of contamination and adherence to the protocols. Following debriefing, a repeat simulation was conducted. The use of a dye highlighted the points of contamination. The study subjects provided feedback on the usefulness of the session and practical difficulties encountered in adapting to the new protocols. Results: The average contamination scores decreased by 3.4 (95% confidence interval (CI): 2.4-4.4, P < 0.001) in the post-debrief session. Adherence to the steps of the modified protocol improved by a score of 2.7 (CI: 3.6-1.83) among anaesthesiologists and by 4.3 (CI: 5.3-3.3) among technicians. Further, 93% felt that the use of the colour indicator reinforced awareness of the possible points of contamination. Conclusion: Simulation with a low-fidelity mannequin by using colour indicator for secretions is an effective teaching tool to reduce health hazards during airway management in COVID-19 times. |
---|---|
ISSN: | 0019-5049 0976-2817 |