Simultaneous multielement extraction with the Mehlich-1 solution for Southern Brazilian soils determined by ICP-OES and the effects on the nutrients recommendations to crops Extração multielementar simultânea com a solução de Mehlich-1 para solos do sul do Brasil e determinação por espectrofotometria de emissão ótica por plasma induzido e os efeitos nas recomendações de adubação para as culturas
The amounts of macro (P, K, Ca and Mg) and micronutrients (Cu and Zn) extracted with the Mehlich-1 (M1) solution, by the 1.0 mol L-1 KCl (KCl) and with the 0.1 mol L-1 HCl (HCl) for representative soil types of the Rio Grande do Sul state (Brazil) were compared with those extracted with the Mehlich-...
Gespeichert in:
Veröffentlicht in: | Revista brasileira de ciência do solo 2010-02, Vol.34 (1), p.125-132 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The amounts of macro (P, K, Ca and Mg) and micronutrients (Cu and Zn) extracted with the Mehlich-1 (M1) solution, by the 1.0 mol L-1 KCl (KCl) and with the 0.1 mol L-1 HCl (HCl) for representative soil types of the Rio Grande do Sul state (Brazil) were compared with those extracted with the Mehlich-1 solution determined with the inductively coupled plasma optical emission spectroscopy (ICP). The amounts of nutrients extracted by the different methods showed high correlation coefficients. On average, the Mehlich-1 solution extracted similar amounts of P, determined with colorimetric and ICP methods, and, K determined with emission and ICP. The amounts of Ca and Mg extracted with the Mehlich-1 solution, determined by ICP, were similar to those extracted with the KCl solution determined by the atomic absorption spectrophotometry. The amounts of Cu and Zn extracted with the Mehlich-1 solution, determined by the ICP, were higher than those extracted with the 0.1 mol L-1 HCl determined by the atomic absorption spectrophotometry. The results indicate that the Mehlich-1 solution and ICP can be used for simultaneous multielement extraction and determination for Southern Brazilian soils. However, a conversion factor for values interpretation is needed. The use of the conversion factor to determine the K availability index in soils is adequate and does not affect the K recommendations for crops in southern Brazilian soils.As quantidades de macro (P, K, Ca e Mg) e micronutrientes (Cu e Zn) extraídos com a solução de Mehlich-1 (M1), por KCl 1,0 mol L-1 (KCl) e com o HCl 0,1 mol L-1 (HCl), em solos representativos do Rio Grande do Sul, foram comparadas com as quantidades de nutrientes extraídos com a solução de Mehlich-1 determinados por espectrofotometria de emissão ótica por plasma induzido (ICP-OES). Os teores de nutrientes extraídos pelos diferentes métodos tiveram alto grau de correlação. Em média, a solução de Mehlich-1 extraiu quantidades semelhantes de P determinado por colorimetria e por ICP, bem como de K determinado por emissão e ICP. Os teores de Ca e Mg extraídos com a solução de Mehlich-1, determinados por ICP, foram semelhantes aos dos extraídos com a solução de KCl determinada por espectrofotometria de absorção atômica. Os teores de Cu e Zn extraídos com a solução de Mehlich-1, determinados por ICP, foram maiores do que os extraídos com a solução de HCl determinada por espectrofotometria de absorção atômica. Os resultados indicam que a solução de Mehlich |
---|---|
ISSN: | 0100-0683 1806-9657 |
DOI: | 10.1590/S0100-06832010000100013 |