Comparison of Fracture Resistance of Primary Incisors Restored with Different Intracanal-Reinforcement Materials

To evaluate the effects of placing short posts made of different restorative materials on the fracture resistance of root canals in primary incisors of primary teeth. The root canals of 40 extracted primary incisors were prepared and filled with Vitapex and randomly divided into five groups of 8 eac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical, cosmetic and investigational dentistry cosmetic and investigational dentistry, 2021-01, Vol.13, p.507-512
Hauptverfasser: Salama, Fouad, Abdelmegid, Faika, Alhussain, Mohammed, Muaddi, Hasan, AlMaflehi, Nassr, Alhowaish, Latifa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To evaluate the effects of placing short posts made of different restorative materials on the fracture resistance of root canals in primary incisors of primary teeth. The root canals of 40 extracted primary incisors were prepared and filled with Vitapex and randomly divided into five groups of 8 each. In Groups 1-4, a post space was created and filled with different restorative materials (Tetric N-Ceram Bulk Fill, AeliteFlo, Filtek Z250 XT, and GC Fuji II LC capsule), while Group 5 was kept filled with Vitapex as a control. Fracture resistance was measured using a universal testing machine at a 0.5-mm/min crosshead speed. The results were statistically analyzed and compared. The highest fracture resistance was recorded for GC Fuji II LC capsules [439.82 N] and control [423.37 N], while the lowest fracture resistance was recorded for Tetric N Ceram Bulk Fill (239.91 N). A multiple comparison test showed that the Tetric N-Ceram Bulk Fill had a significantly lower average value than AeliteFlo (P = 0.030), as well as a significantly lower average value than GC Fuji II LC capsule (P = 0.001), and a significantly lower average value than the control group (P = 0.002). Multiple comparison tests showed no significant difference between Tetric N-Ceram Bulk Fill and Filtek Z250 XT (P = 0.39). The fracture resistance of primary incisor root canals differs according to the material used for the intracanal posts. Three-millimeter intracanal posts in the primary incisors showed the highest fracture resistance for the teeth restored with GC Fuji II LC capsules and the control.
ISSN:1179-1357
1179-1357
DOI:10.2147/CCIDE.S335333