A novel method for improving the electrochemical properties by modifying conductive polymer on 3D printed nanocarbon electrode

•Conductive polymer composites with adhesion were prepared by a simple method.•This conducting polymer composites have excellent stability.•For the first time, we combined conductive polymers with 3D printed electrodes.•The sensor was used to determine chlorogenic acid in coffee solution. The techno...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrochemistry communications 2024-08, Vol.165, p.107754, Article 107754
Hauptverfasser: Liao, Meifang, Yang, Yaxin, Ou, Jing, Yang, Honglin, Dai, Xuemei, Zhong, Lian, Wen, Jie, Jiang, Yanyu, Wang, Lujun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Conductive polymer composites with adhesion were prepared by a simple method.•This conducting polymer composites have excellent stability.•For the first time, we combined conductive polymers with 3D printed electrodes.•The sensor was used to determine chlorogenic acid in coffee solution. The technology of 3D printing has emerged as a potent tool for the preparation of 3D-printed electrode. Using commercial graphene/polylactic acid (PLA) composite filaments as printed materials, fused deposition modeling as 3D-printed technique, 3D printed electrodes (3DEs) were created in this work. Gold nanoparticles (AuNPs) and the composites of poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) were used to modify the activated 3DEs for constructing a novel electrode (SACP@Au@3DE), and in this work chlorogenic acid (CGA) was regarded as a probe for testing the performance of SACP@Au@3DE. The surface physicochemical properties of the prepared 3DEs were characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The electrochemical properties of the prepared 3DEs were investigated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. The constructed SACP@Au@3DE can be used to determine CGA at concentrations ranging from 10 to 400 μM with a limit of detection (LOD) of 4.13 μM. Ultimately, the SACP@Au@3DE sensor was used for CGA detection in coffee powder sample to explore the potential for real sample analysis. This work opens the novel avenue of using conductive polymer modified 3D-printed electrode in the field of sensor.
ISSN:1388-2481
1873-1902
DOI:10.1016/j.elecom.2024.107754