Apical Extrusion of Debris in Mesiobuccal Root of Maxillary Molars with Five Rotary File Systems

Introduction: Flare-ups in endodontics are multifactorial and may cause severe discomfort to the patient. Apical extrusion while preparing root canal space in any form such as debris, bacteria or irrigants has been found to be associated with many flare-up events and may even lead to treatment failu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical and diagnostic research 2018-05, Vol.12 (5), p.ZC05-ZC09
Hauptverfasser: Kumar, Gali Praveen, Godavarthy, Divya Sri, Yarlagadda, Manasa, Beesetty, Nataraj, Killi, Nidesh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Flare-ups in endodontics are multifactorial and may cause severe discomfort to the patient. Apical extrusion while preparing root canal space in any form such as debris, bacteria or irrigants has been found to be associated with many flare-up events and may even lead to treatment failure. Aim: To quantitatively evaluate apically extruded debris with five rotary instrumentation systems in mesiobuccal root of maxillary molars. Materials and Methods: A total of 120 human maxillary first molars extracted between January and March of 2017 in oral and maxillofacial surgery department at Drs. Sudha and Nageswara Rao Siddhartha Institute of Dental Sciences, Gannavaram, Andhra Pradesh, India, were included in the current study. Only the Molars with a three rooted pattern were selected and mesiobuccal root was used to evaluate apical extrusion. An experimental apparatus for evaluation of extruded debris as previously described by Myers and Montgomery was fabricated. All samples were divided into six groups (n=20 each) and instrumentation was done with five rotary file systems (K3XF, ProTaper NEXT, HyFlex CM, Revo-S, and FLEXICON) and HAND K FILES which served as control. The weight of the micro tubes in the apparatus before and after the instrumentation was calculated using an electronic weighing balance with a minimum sensitivity of 10-4 and weights were compared to quantify the apical extrusion. Statistical analysis was analysed with the ANOVA and multiple comparison (Posthoc-Dunnett and Tukey) tests. Results: It was found that all the instrumentation systems showed a considerable amount of apical debris extrusion. HAND K FILES were associated with most debris extrusion compared to all rotary files (p
ISSN:2249-782X
0973-709X
DOI:10.7860/JCDR/2018/34261.11470