Possibility of Substitution of LOD1 Data for LOD2 Data on Photovoltaic Potential Estimation at City Districts Level Using a 3D City Model

We developed a system to estimate the photovoltaic (PV) potential of urban buildings using a 3D city model at level of detail 2 (LOD2), considering an arrangement of solar panels. Although the PV potential estimation of buildings at the level of city districts prefers LOD2 data, many urban city dist...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ISPRS annals of the photogrammetry, remote sensing and spatial information sciences remote sensing and spatial information sciences, 2024-10, Vol.X-4-2024, p.231-238
Hauptverfasser: Matsuoka, Ryuji, Koide, Kazumasa, Abe, Ryogo, Kato, Saki, Takemoto, Takashi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We developed a system to estimate the photovoltaic (PV) potential of urban buildings using a 3D city model at level of detail 2 (LOD2), considering an arrangement of solar panels. Although the PV potential estimation of buildings at the level of city districts prefers LOD2 data, many urban city districts with buildings capable of installing solar panels on façades do not have LOD2 data owing to the high production cost of LOD2 data. Therefore, we investigated the possibility of utilising LOD1 data instead of LOD2 data in the PV potential estimation of buildings at the level of city districts. We conducted an experiment in the investigation using 3D city model data from 24 city districts, which are most of the large cities with LOD2 data in Japan. The experiment results suggest that LOD1 would not be a substitute for LOD2 data in the PV potential estimation of building roofs. The cause of the inadaptability is that most roofs in LOD2 buildings have more small polygons than LOD1 building roofs. Roofs of a LOD2 building with many small polygons have fewer solar panels than roofs of a LOD1 building with a large polygon. On the contrary, the experiment results indicate that LOD1 may be a substitute directly for LOD2 in the PV potential estimation of building façades that are expected to be used as a mounting platform for solar panels in urban buildings from now on. The average of the relative differences in the calculated PV potential of building façades between using LOD1 data and using LOD2 data is approximately 10% in the experiment.
ISSN:2194-9050
2194-9042
2194-9050
DOI:10.5194/isprs-annals-X-4-2024-231-2024