Restoration of the patient-specific anatomy of the distal fibula based on a novel three-dimensional contralateral registration method

Purpose Posttraumatic fibular malunion alters ankle joint biomechanics and may lead to pain, stiffness, and premature osteoarthritis. The accurate restoration is key for success of reconstructive surgeries. The aim of this study was to analyze the accuracy of a novel three-dimensional (3D) registrat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Experimental Orthopaedics 2022-05, Vol.9 (1), p.48-48, Article 48
Hauptverfasser: Calek, Anna-Katharina, Hodel, Sandro, Hochreiter, Bettina, Viehöfer, Arnd, Fucentese, Sandro, Wirth, Stephan, Vlachopoulos, Lazaros
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Posttraumatic fibular malunion alters ankle joint biomechanics and may lead to pain, stiffness, and premature osteoarthritis. The accurate restoration is key for success of reconstructive surgeries. The aim of this study was to analyze the accuracy of a novel three-dimensional (3D) registration algorithm using different segments of the contralateral anatomy to restore the distal fibula. Methods Triangular 3D surface models were reconstructed from computed tomographic data of 96 paired lower legs. Four segments were defined: 25% tibia, 50% tibia, 75% fibula, and 75% fibula and tibia. A surface registration algorithm was used to superimpose the mirrored contralateral model on the original model. The accuracy of distal fibula restoration was measured. Results The median rotation error, 3D distance (Euclidean distance), and 3D angle (Euler’s angle) using the distal 25% tibia segment for the registration were 0.8° (− 1.7–4.8), 2.1 mm (1.4–2.9), and 2.9° (1.9–5.4), respectively. The restoration showed the highest errors using the 75% fibula segment (rotation error 3.2° (0.1–8.3); Euclidean distance 4.2 mm (3.1–5.8); Euler’s angle 5.8° (3.4–9.2)). The translation error did not differ significantly between segments. Conclusion 3D registration of the contralateral tibia and fibula reliably approximated the premorbid anatomy of the distal fibula. Registration of the 25% distal tibia, including distinct anatomical landmarks of the fibular notch and malleolar colliculi, restored the anatomy with increasing accuracy, minimizing both rotational and translational errors. This new method of evaluating malreductions could reduce morbidity in patients with ankle fractures. Level of evidence IV
ISSN:2197-1153
2197-1153
DOI:10.1186/s40634-022-00487-7