Disagreement in middle ear volume estimation between tympanometry and three-dimensional volume reconstruction in the context of tympanic membrane perforation

Introduction: Middle ear volume (MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes (TMs).Methods: Middle ears were identified from 36 patients ranging 18e89 ye...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of otology 2017-06, Vol.12 (2), p.74-79
Hauptverfasser: Carpenter, David J., Tucci, Debara L., Kaylie, David M., Frank-Ito, Dennis O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Middle ear volume (MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes (TMs).Methods: Middle ears were identified from 36 patients ranging 18e89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography (CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction (3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles (1 ? smallest; 4 ? largest) and across increasing states of middle ear disease using KruskaleWallis and Wilcoxon testing with Bonferroni correction. Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average (i.e. (Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles (p ? 0.0024), fourth and second quartiles(p ? 0.0024), third and first quartiles (p ? 0.0048), and third and second quartiles (p ? 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease (p ? 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values.
ISSN:1672-2930
2524-1753
DOI:10.1016/j.joto.2017.04.001