Variability of Standard Liver Volume by 2D Ultrasound: A Cross-sectional Study from Eastern India

Introduction: Liver volume estimation is an essential component prior to major hepatic surgery and liver transplantation. Liver volume is evaluated with different formulae, gold standard Computed Tomography (CT) volumetry and Magnetic Resonance Imaging (MRI). As per literature review, studies compar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical and diagnostic research 2021-04, Vol.15 (4), p.TC01-TC04
Hauptverfasser: Ain, Partha Sarathi, Roy, Uttam Kumar, Sen, Krishna, Ray, Debes, Pal, Jayanta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Liver volume estimation is an essential component prior to major hepatic surgery and liver transplantation. Liver volume is evaluated with different formulae, gold standard Computed Tomography (CT) volumetry and Magnetic Resonance Imaging (MRI). As per literature review, studies comparing ultrasonography with formula based liver volume estimation are very few. Ultrasonography is non-invasive in nature and inexpensive. It is gaining popularity among clinicians as it helps in rapid evaluation of liver volumes. Aim: To compare variability of liver volume using 2D ultrasound with a standard well-established method based on formula derived by Johnson et al. Materials and Methods: This was a cross-sectional study done between August-October 2020 and patients were selected by the physician from general Outpatient Department (OPD) pool and clinically screened for further biochemical studies. Participants aged 20-60 years with normal liver function test were recruited in the study. Images were taken on a Siemens Ultrasound System. Study variables included were liver volumes estimated by two methods, age, weight, height and Body Surface Area (BSA). F test was used to compare variability between liver volumes estimated by two different methods. Bivariate correlation between ultrasonography-based liver volume and different body indices was also tested. Results: Variability comparison using F test shows no significant difference (F=1.095, df1=149, df2=149, p=0.29). Liver volumes estimated by two methods showed good correlation with each other and is significant at the 0.01 level, r=0.574. The mean difference (125 cc) in volumes between two methods were statistically significant (t=10.92, degree of freedom=149, p
ISSN:2249-782X
0973-709X
DOI:10.7860/JCDR/2021/47353.14716