Efficiency of urban greening systems with maximized latent heat effect in urban heat island and climate change mitigation
•The latent heat of evaporation effect contributes to canopy layer urban heat island mitigation.•Quantitative figures of temperature reduction contribute to establishing eco-friendly urban planning.•New greening systems that maximize the latent heat of evaporation were developed.•The developed rooft...
Gespeichert in:
Veröffentlicht in: | Environmental challenges (Amsterdam, Netherlands) Netherlands), 2024-04, Vol.15, p.100956, Article 100956 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The latent heat of evaporation effect contributes to canopy layer urban heat island mitigation.•Quantitative figures of temperature reduction contribute to establishing eco-friendly urban planning.•New greening systems that maximize the latent heat of evaporation were developed.•The developed rooftop greening system contributes to reducing the temperature of the entire city.•The developed system can reduce the temperature of the entire city by 2 °C.
Street, wall, and rooftop greening systems are essential for urban heat reduction and carbon neutrality. In this study, we compared the temperature-reducing effect of current and developed technologies that maximize the latent heat of evaporation through such greening systems. A research site with the maximum urban heat island effect was selected by analyzing the vulnerability of Suwon City, Korea. The latent heat of evaporation for each method was determined by conducting actual measurements and verified by performing computational fluid dynamics simulations. Based on the results of statistical techniques, the validated model was highly reliable. When developed technologies were applied, the temperature of the entire city was reduced by approximately 2 °C. Compared with the existing street greening system, the developed technology achieved a temperature reduction effect even at a distance of 5 m. Current wall greening systems only have a temperature reduction effect at 1 m, but that of the developed technology was approximately 1 °C even at a distance of 2 m. The existing rooftop greening system had a temperature reduction effect only at the height of 1.2 m, whereas that of the developed technology was effective even at 6 m, contributing to a reduction in the temperature of the entire city. |
---|---|
ISSN: | 2667-0100 2667-0100 |
DOI: | 10.1016/j.envc.2024.100956 |