Successful double lumen tube insertion in a patient with unanticipated laryngeal and tracheal web
A 45-year-old female patient admitted for surgical management of carcinoma esophagus, presented with difficulty in insertion of left-sided 37 F and 35 F double lumen tube (Mallinckrodt® Broncho-Cath). Fiberoptic bronchoscopy revealed a subglottic web in the larynx just below the vocal cords and a tr...
Gespeichert in:
Veröffentlicht in: | Annals of cardiac anaesthesia 2011-09, Vol.14 (3), p.211-213 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 45-year-old female patient admitted for surgical management of carcinoma esophagus, presented with difficulty in insertion of left-sided 37 F and 35 F double lumen tube (Mallinckrodt® Broncho-Cath). Fiberoptic bronchoscopy revealed a subglottic web in the larynx just below the vocal cords and a tracheal web just above the carina. Differential lung ventilation could be achieved with a 35 F internal diameter double lumen tube (Portex® Blueline® Endobronchial tube). |
---|---|