Percutaneous nephrostomy for nondilated renal collecting system with ultrasound and fluoroscopic guidance: The results of a 10-year experience

PURPOSE This study aimed to evaluate the technical success rate, complications, and radiation doses of ultrasound- and fluoroscopy-guided percutaneous nephrostomy (PCN) in patients with a nondi- lated renal collecting system. METHODS Over a 10-year period, 50 patients were referred for PCN of 60 kid...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and Interventional Radiology 2022-05, Vol.28 (3), p.244-248
Hauptverfasser: Won, Jung Ho, Yang, Woo Jin, Shin, Ji Hoon, Kim, Jong Woo, Chu, Hee Ho, Lee, Sang Min, Choi, Ho Cheol, Park, Sung Eun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSE This study aimed to evaluate the technical success rate, complications, and radiation doses of ultrasound- and fluoroscopy-guided percutaneous nephrostomy (PCN) in patients with a nondi- lated renal collecting system. METHODS Over a 10-year period, 50 patients were referred for PCN of 60 kidneys with a nondilated renal collecting system. The patients included 22 males and 28 females with a mean age of 63.2 years (range: 35-87 years). The most common reason for PCN in these patients was postoperative ure- teral leaks and/or fistula (21/50 patients). PCN was performed under ultrasound and fluoroscopic guidance. During PCN, intravenous contrast media or diuretics were not used. Technical success rate, complications, procedure time, and radiation exposure of the procedure were retrospec- tively evaluated. RESULTS Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system showed a suc- cess rate of 83.3% (50/60 kidneys) in the initial attempt. Four PCNs were repeated and were suc- cessful after the initial PCN failure. There was 1 major complication of bleeding that required transfusion in 1.9% (1/54) PCNs and there were minor complications of transient gross hematuria through the PCN catheter in 31.5% (17/54) PCNs. Mean duration of the procedure was 15.97 ± 7.81 min and median fluoroscopy time was 4.2 min (range: 1.2-15.3 min). Median dose area product and cumulative dose were 345.37 μGy·m2 (range: 42.57-1659.76 μGy·m2) and 46.9 mGy (range: 7.7-267.8 mGy), respectively. CONCLUSION Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system was feasible with acceptable technical success rate, complication rate, procedure time, and radiation exposure.
ISSN:1305-3825
1305-3612
DOI:10.5152/dir.2022.20728