The cost effectiveness of intensity-modulated radiation therapy and three-dimensional conformal radiotherapy in the treatment of head and neck cancers
Purpose Intensity-modulated radiotherapy is developed as a replacement for 3-dimensional conformal radiation therapy. Considering the difference in costs and effectiveness of these interventions, the aim of this study was to compare the cost effectiveness of intensity-modulated radiation therapy and...
Gespeichert in:
Veröffentlicht in: | Radiation oncology (London, England) England), 2023-08, Vol.18 (1), p.1-138, Article 138 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose Intensity-modulated radiotherapy is developed as a replacement for 3-dimensional conformal radiation therapy. Considering the difference in costs and effectiveness of these interventions, the aim of this study was to compare the cost effectiveness of intensity-modulated radiation therapy and three-dimensional conformal radiotherapy in the treatment of head and neck cancer in east of Iran. Methods A Markov model including six states based on xerostomia and dysphagia was developed to estimate the incremental cost effectiveness ratio from the perspective of societal. Cost and quality of life data were collected from 97 respondents via a checklist and EuroQol-5Dimension questionnaire. The robustness of results was examined by deterministic and probabilistic sensitivity analysis. All analysis were conducted with Treeage software. Results The results of this study showed that the cost and quality adjusted life years for 3-dimensional conformal radiation therapy were 9209.76 and 3.63 respectively. However, the cost and quality adjusted life years for intensity-modulated radiotherapy were 12562.90 and 3.17 respectively. Therefore, 3-dimensional conformal radiation therapy produced 0.45 more quality adjusted life years than intensity-modulated radiotherapy and saved $3353. According to the incremental cost effectiveness ratio, 3-dimensional conformal radiation therapy as compared to intensity-modulated radiotherapy saved $7367.27 per quality adjusted life years. These results confirmed by sensitivity analysis. Conclusion This study concluded that in the treatment of head and neck cancer, the 3-dimensional conformal radiation therapy method appears to be cost-effective when compared with intensity-modulated radiotherapy. Keywords: Cost-effectiveness analysis, Radiotherapy, Conformal, Radiotherapy, intensity-modulated, Head and Neck Neoplasms |
---|---|
ISSN: | 1748-717X 1748-717X |
DOI: | 10.1186/s13014-023-02327-z |