Performance comparison of the single-refrigerant cascade refrigerating system

In the food refrigeration industry, the single-stage compression refrigerating system cannot meet the operating conditions of a high-pressure ratio when the evaporating temperature decreases. The cascade refrigerating system (CRS) is an alternative technical solution to solving the mentioned problem...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy reports 2022-11, Vol.8, p.8259-8270
Hauptverfasser: Sun, Zhili, Quan, Jianhua, Wang, Yi’an, Li, Ruishen, Peng, Jie, Zhang, Haoran, Xu, Jiapei, Sun, Huan, Tian, Shen, Dong, Shengming, Hu, Kaiyong, Chen, Wenxiang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the food refrigeration industry, the single-stage compression refrigerating system cannot meet the operating conditions of a high-pressure ratio when the evaporating temperature decreases. The cascade refrigerating system (CRS) is an alternative technical solution to solving the mentioned problem. This paper studied single-refrigerant pairs used in CRS. The single-refrigerant pairs R32/R32, R125/R125, R1270/R1270, R143a/R143a, R404A/R404A, R407A/R407A, R410A/R410A, and R507A/R507A were adopted to evaluate their operating characteristics compared with those of the traditional R23/R404A CRS. The operation adaptability of the compressor, the optimal operating parameters, the coefficient of performance (COP), and the seasonal energy efficiency ratio (SEER) were analyzed under different single-refrigerant pairs. The results show that the COP of the traditional CRS can be improved by using single-refrigerant pairs. The COP of R32/R32, R125/R125, R1270/R1270, R143a/R143a, R404A/R404A, R410A/R410A, and R507A/R507A were improved by 19.48%, 8.08%, 21.54%, 14.33%, 11.00%, 15.64%, and 12.11%, respectively. In addition, the SEER of the single-refrigerant CRS was higher than that of R23/R404A CRS. This could reduce energy consumption and save energy in typical cities in five major climatic zones of China. Considering COP, flammability, and safety, the application of R1270/R1270 and R32/R32 in a CRS with a low refrigerant charge is recommended. Meanwhile, R410A/R410A may be used in a CRS with a large refrigerant charge. These results provide a theoretical basis for the application of the single-refrigerant CRS.
ISSN:2352-4847
2352-4847
DOI:10.1016/j.egyr.2022.06.055