Hyperpolarized 129Xe MRI and spectroscopy of gas-exchange abnormalities in bilateral lung transplant recipients

Background: There is currently no sensitive, noninvasive method of screening for chronic lung allograft dysfunction (CLAD), the primary barrier to long-term survival after lung transplant. Conventional pulmonary function testing is imprecise absent a sustained decline. Hyperpolarized 129Xe magnetic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JHLT open 2024-08, Vol.5, p.100117, Article 100117
Hauptverfasser: Simmons, Austin, Mummy, David, Zhang, Shuo, Leewiwatwong, Suphachart, Palmer, Scott, Driehuys, Bastiaan, Ali, Hakim Azfar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: There is currently no sensitive, noninvasive method of screening for chronic lung allograft dysfunction (CLAD), the primary barrier to long-term survival after lung transplant. Conventional pulmonary function testing is imprecise absent a sustained decline. Hyperpolarized 129Xe magnetic resonance imaging (MRI) is a sensitive tool for 3-dimensional imaging of regional pulmonary ventilation and gas-exchange abnormalities and may aid in early detection of CLAD. Methods: Adult patients, post bilateral lung transplant, were screened for CLAD based on the International Society for Heart and Lung Transplantation criteria. Those with established allografts (n = 10) underwent 129Xe gas-exchange MRI and spectroscopy and were compared to results from 16 young healthy volunteers and 16 age-matched healthy volunteers. One lung transplant recipient was excluded from the final data analysis due to a concurrent lung infection found incidentally after MRI. Imaging provided quantitative maps of the ventilation defect percent (VDP), membrane high percent, and red blood cell (RBC) defect percent. Spectroscopy yielded RBC/membrane ratio, oxygenation-dependent RBC shift, and RBC oscillation amplitude. Results: The analysis included 9 lung transplant recipients, 7 with CLAD and 2 without. CLAD patients exhibited VDP values consistent with their forced expiratory volume in 1 second (FEV1) decline (rho = 0.79, p = 0.048). Hemoglobin-corrected RBC transfer was reduced in all transplant recipients vs young healthy controls (median [first quartile-third quartile] of 13% [9%-22%] vs 2% [1.75%-3%], p = 0.003) as well as vs age-matched controls (5.5% [2%-9.25%], p = 0.039). Spectroscopy demonstrated reduced RBC/membrane signal (0.26 [0.17-0.31] vs 0.62 [0.50-0.66], p 
ISSN:2950-1334
2950-1334
DOI:10.1016/j.jhlto.2024.100117