Development and validation of self-reported line drawings of the modified Beighton score for the assessment of generalised joint hypermobility
The impracticalities and comparative expense of carrying out a clinical assessment is an obstacle in many large epidemiological studies. The purpose of this study was to develop and validate a series of electronic self-reported line drawing instruments based on the modified Beighton scoring system f...
Gespeichert in:
Veröffentlicht in: | BMC medical research methodology 2018-01, Vol.18 (1), p.11-11, Article 11 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The impracticalities and comparative expense of carrying out a clinical assessment is an obstacle in many large epidemiological studies. The purpose of this study was to develop and validate a series of electronic self-reported line drawing instruments based on the modified Beighton scoring system for the assessment of self-reported generalised joint hypermobility.
Five sets of line drawings were created to depict the 9-point Beighton score criteria. Each instrument consisted of an explanatory question whereby participants were asked to select the line drawing which best represented their joints. Fifty participants completed the self-report online instrument on two occasions, before attending a clinical assessment. A blinded expert clinical observer then assessed participants' on two occasions, using a standardised goniometry measurement protocol. Validity of the instrument was assessed by participant-observer agreement and reliability by participant repeatability and observer repeatability using unweighted Cohen's kappa (k). Validity and reliability were assessed for each item in the self-reported instrument separately, and for the sum of the total scores. An aggregate score for generalised joint hypermobility was determined based on a Beighton score of 4 or more out of 9.
Observer-repeatability between the two clinical assessments demonstrated perfect agreement (k 1.00; 95% CI 1.00, 1.00). Self-reported participant-repeatability was lower but it was still excellent (k 0.91; 95% CI 0.74, 1.00). The participant-observer agreement was excellent (k 0.96; 95% CI 0.87, 1.00). Validity was excellent for the self-report instrument, with a good sensitivity of 0.87 (95% CI 0.81, 0.91) and excellent specificity of 0.99 (95% CI 0.98, 1.00).
The self-reported instrument provides a valid and reliable assessment of the presence of generalised joint hypermobility and may have practical use in epidemiological studies. |
---|---|
ISSN: | 1471-2288 1471-2288 |
DOI: | 10.1186/s12874-017-0464-8 |