Factors of estimating flatness error as a surface requirement of exploitation

This study considers the impact of surface quality (surface roughness) on estimating flatness error when measurements are performed using coordinate measuring machine (CMM). Flatness error is estimated using various association methods and various sample sizes, while the distribution of sample point...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Metalurgija 2015-01, Vol.54 (1), p.239-242
Hauptverfasser: M. Hadžistević, B. Štrbac, V. Spasić Jokić, M. Delić, M. Sekulić, J. Hodolič
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study considers the impact of surface quality (surface roughness) on estimating flatness error when measurements are performed using coordinate measuring machine (CMM). Flatness error is estimated using various association methods and various sample sizes, while the distribution of sample points is done randomly on a flatness feature using the random number generator in Matlab. ANOVA is used for determining the significance of differences between the observed groups. It has been determined that the estimate of flatness error is affected by the processing method, the number of sample points and associative method used, but not by surface roughness.
ISSN:0543-5846
1334-2576