Bayesian analysis of high-resolution ultrasonography and guided fine needle aspiration cytology in diagnosis of palpable thyroid nodules
To evaluate diagnostic accuracy of high-resolution ultrasonography in differentiation of benign and malignant thyroid nodules in comparison to results of guided fine needle aspiration cytology based on the Bayes rule. To assess the validity of ultrasonography results of thyroid nodules in comparison...
Gespeichert in:
Veröffentlicht in: | Brazilian journal of otorhinolaryngology 2018-01, Vol.84 (1), p.20-27 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To evaluate diagnostic accuracy of high-resolution ultrasonography in differentiation of benign and malignant thyroid nodules in comparison to results of guided fine needle aspiration cytology based on the Bayes rule.
To assess the validity of ultrasonography results of thyroid nodules in comparison to guided fine needle aspiration cytology findings.
This study was done on randomly chosen 80 patients presented with palpable thyroid nodules, undergone real-time sonographic evaluation of thyroid nodules to characterize features, internal consistency, margins, echotexture, calcification, peripheral lucent halo and vascularity. Ultrasonography guided fine needle aspiration cytology studies of thyroid nodules were done.
Palpable thyroid nodules were highly prevalent in fourth and fifth decades of life with female–male ratio, 4:1. Solid internal consistency was demonstrated by 75% malignant nodules. Hypoechogenicity and intra-nodular micro-calcifications were observed in 92% malignant nodules; 83% malignant nodules had intra-nodular vascularity and absence of peripheral halo. The pre-test prevalence of malignant nodules in the targeted population was 17.5%. As type I error, 2.5% false-positive cases and as type II error, 5.0% false-negative cases were detected. Values of sensitivity and specificity of the ultrasonography test were 71.43 and 96.97%, respectively.
Malignant thyroid nodules demonstrated ultrasonography characteristics of hypoechoic texture, intra-nodular micro-calcifications, solid consistency, internal vascularity and absence of peripheral halo. The ultrasonography test has 92.5% diagnostic accuracy to differentiate malignant from benign lesions in comparison to the gold standard fine needle aspiration cytology test.
Avaliar a precisão diagnóstica da ultrassonografia de alta resolução na diferenciação de nódulos tireoidianos benignos e malignos em comparação com os resultados da citologia de aspiração por agulha fina baseada na regra de Bayes.
Avaliar a validade dos resultados da USG de nódulos da tireoide em comparação com os resultados obtidos por citologia de aspiração por agulha fina.
Esse estudo foi realizado em 80 pacientes selecionados aleatoriamente, que apresentavam nódulos palpáveis da tireoide, submetidos à avaliação ultrassonográfica em tempo real de nódulos da tireoide para estabelecer características, consistência interna, margens, ecotextura, calcificação, halo lucente periférico e vascularização. Foram realizados estudos por citolo |
---|---|
ISSN: | 1808-8694 1808-8686 1808-8686 |
DOI: | 10.1016/j.bjorl.2016.10.010 |