Surgical Outcome of Epicanthus and Telecanthus Correction by Double Z-Plasty and Trans-Nasal Fixation with Prolene Suture in Blepharophimosis Syndrome

Blepharophimosis Syndrome (BPES) is a complex and rare disease characterized by epicanthus inversus, telecanthus, lateral ectropion, narrowed or shortened inter-palpebral fissure distance and ptosis. It is mostly bilateral and may or may not be symmetrical. It is typically inherited as an autosomal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical and diagnostic research 2017-03, Vol.11 (3), p.NC05-NC08
Hauptverfasser: Mandal, Salil Kumar, Mandal, Aparna, Fleming, James Christian, Goecks, Tara, Meador, Andrew, Fowler, Brian T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Blepharophimosis Syndrome (BPES) is a complex and rare disease characterized by epicanthus inversus, telecanthus, lateral ectropion, narrowed or shortened inter-palpebral fissure distance and ptosis. It is mostly bilateral and may or may not be symmetrical. It is typically inherited as an autosomal dominant trait. In sporadic cases, the disease may occur without a prior family history as a genetic mutation from a deletion or translocation of the gene, which maps to chromosome 3q23. Surgical treatment of this disease poses an oculoplastic challenge due to multiple complex eyelid deformities. To evaluate the functional and cosmetic outcome of telecanthus and epicanthus correction by a Mustarde's rectangular double Z-Plasty and trans-nasal fixation using 1-0 prolene suture in BPES. This was prospective, interventional study of 16 patients over a period of three years. In this study, all patients had BPES with prominent epicanthus and telecanthus. Mustarde's double Z-plasty and trans-nasal fixation with 1-0 prolene suture was performed in the first of a two-stage operation. If ectropion was present, the lateral ectropion was corrected by a base-out flap transfer from the upper eyelid to the lower eyelid. After three months, a 2 stage was undertaken, involving a lateral canthoplasty for horizontal widening of a short palpebral fissure and a tarso frontalis sling with silicone rod for correction of moderate to severe ptosis. Patients were followed up for six months to one year with postoperative ophthalmologic examinations and photographs. Out of 16 patients, 10 were females and six were males. All the patients had bilateral involvement. In this study preoperative Inner Intercanthal Distance (IICD) ranged from 38 mm to 42 mm and the mean IICD was 41.2±0.57 mm. Postoperative IICD ranged from 31 mm to 34 mm. Horizontal Palpebral Fissure Length (HPFL) ranged from 20 mm to 23 mm and the mean value of HPFL was 21.50 mm preoperatively. Postoperative HPFL ranged from 26 mm to 29 mm and had a mean value of 28.50 mm, which was much improved after a combined correction of telecanthus and lateral canthoplasty. The mean preoperative IICD and HPFL ratio was 1.77 and was reduced to a postoperative value of 1.2. The Marginal Reflex Distance1 (MRD-1) test value improved from +1.25 mm to +3.50 mm postoperatively after placement of a tarsofrontalis sling with silicone rod using the Fox's Pentagon technique. In this study, two eyes had minimal unequal correction but were cosmetica
ISSN:2249-782X
0973-709X
DOI:10.7860/JCDR/2017/25651.9496