Difference in implant design affects midflexion rotational laxity in cruciate-retaining total knee arthroplasty: a computer navigation study
Purpose This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate-retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity. Methods Sixty-three kn...
Gespeichert in:
Veröffentlicht in: | Journal of Experimental Orthopaedics 2023-08, Vol.10 (1), p.85-n/a |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
This study aimed to compare midflexion rotational laxity between two different design concept models of cruciate-retaining total knee arthroplasty: symmetrical surface design of neutral joint line obliquity and asymmetrical surface design of varus joint line obliquity.
Methods
Sixty-three knees that underwent cruciate-retaining total knee arthroplasty were evaluated. Manual maximum passive rotational stress without acceleration was applied to the knees under navigation monitoring. Pre-operative and post-operative internal and external rotational angles were measured at 30°, 45°, 60°, and 90° knee flexion.
Results
The post-operative internal rotational laxity was significantly increased compared with pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 9.7° vs 11.1°, 10.6° vs 11.6°, 11.2° vs 12.9°, and 13.2° vs 14.9°;
p
= 0.01, 0.04, 0.001, and 0.008, respectively). The post-operative external rotational laxity was significantly decreased compared to pre-operative levels at 30°, 45°, 60°, and 90° flexion among all subjects (mean 10.8° vs 6.8°, 12.5° vs 9.4°, 12.8° vs 10.0°, and 11.3° vs 9.5°;
p
|
---|---|
ISSN: | 2197-1153 2197-1153 |