Multiparametric cardiovascular magnetic resonance imaging in acute myocarditis: a comparison of different measurement approaches

Myocardial T1 and T2 mapping are reliable diagnostic markers for the detection and follow up of acute myocarditis. The aim of this study was to compare the diagnostic performance of current mapping measurement approaches to differentiate between myocarditis patients and healthy individuals. Fifty pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of cardiovascular magnetic resonance 2019-08, Vol.21 (1), p.54-11, Article 54
Hauptverfasser: Dabir, Darius, Vollbrecht, Thomas M, Luetkens, Julian A, Kuetting, Daniel L R, Isaak, Alexander, Feisst, Andreas, Fimmers, Rolf, Sprinkart, Alois M, Schild, Hans H, Thomas, Daniel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Myocardial T1 and T2 mapping are reliable diagnostic markers for the detection and follow up of acute myocarditis. The aim of this study was to compare the diagnostic performance of current mapping measurement approaches to differentiate between myocarditis patients and healthy individuals. Fifty patients with clinically defined acute myocarditis and 30 healthy controls underwent cardiovascular magnetic resonance (CMR). Myocardial T1 relaxation times, T2 relaxation times, left ventricular (LV) function, T2 ratio, early gadolinium enhancement ratio, and presence of late gadolinium enhancement (LGE) were analysed. Native T1 and T2 relaxation times, as well as extracellular volume fraction (ECV) were measured for the entire LV myocardium (global), within the midventricular short axis slice (mSAX), within the midventricular septal wall (ConSept), and within the remote myocardium (remote). Receiver operating characteristics analysis was performed to compare diagnostic performance. All measurement approaches revealed significantly higher native T1 and T2 relaxation times as well as ECV values in patients compared to healthy controls (p  0.050 for all parameters). Native T1 and T2 mapping allow for accurate detection of acute myocarditis irrespective of the measurement approach used. Even measurements performed exclusively within remote myocardium allow for reliable detection of acute myocarditis, demonstrating diffuse involvement of disease despite a mostly regional or patchy distribution pattern of visible pathologies. The global measurement approach provides the overall best diagnostic performance in acute myocarditis for both T1 and T2 mapping.
ISSN:1097-6647
1532-429X
1532-429X
DOI:10.1186/s12968-019-0568-x