Management of an intraoperatively damaged endotracheal tube in a case of difficult airway using fibre-optic bronchoscope with minimal apnoea period

Damage to the endotracheal tube (ETT) is common in head and neck surgeries, especially in maxillary osteotomy. Airway management in such a crisis is crucial as there is risk of aspiration of blood into lungs, hypoxia and apnoea. This case illustrates a patient with an anticipated difficult airway wh...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Indian journal of anaesthesia 2017-04, Vol.61 (4), p.347-349
Hauptverfasser: Himarani, Jayachandran, Nancy, S Mary, Krishna Kumar Raja, V B, Sundaram, S Shanmuga
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Damage to the endotracheal tube (ETT) is common in head and neck surgeries, especially in maxillary osteotomy. Airway management in such a crisis is crucial as there is risk of aspiration of blood into lungs, hypoxia and apnoea. This case illustrates a patient with an anticipated difficult airway who had an intraoperative damage to the ETT and was successfully managed by re-intubation with fiberoptic bronchoscope in a minimal apnoea period of