Segmentation and region quantification of bubbles in small bowel capsule endoscopy images using wavelet transform
A large number of captured frames by the wireless capsule endoscopy have been contaminated with different amounts of bubbles. Bubbles can degrade the visualization quality of the small intestine mucosa. The aim of this study is to develop an objective method for evaluating the amount of bubbles in W...
Gespeichert in:
Veröffentlicht in: | Informatics in medicine unlocked 2023, Vol.42, p.101364, Article 101364 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A large number of captured frames by the wireless capsule endoscopy have been contaminated with different amounts of bubbles. Bubbles can degrade the visualization quality of the small intestine mucosa. The aim of this study is to develop an objective method for evaluating the amount of bubbles in WCE images.
Frames with varying levels of bubble occlusion were selected from the Kvasir capsule endoscopy dataset. The round shape bubbles have an edge in their boundaries. Edges in the spatial domain correspond to high-frequency bands in the frequency domain. Two automated edge detection approaches have been developed in a rule-based manner and evaluated to assess the amount of bubbles. The first approach involved high pass filtering using fast Fourier transform (FFT), while the second approach has been based on wavelet image decomposition and reconstruction by omitting approximation coefficients subband.
Both Fourier and wavelet transforms obtained approximately the same dice similarity score (DSC), and precision metrics, which were equal to 0.87, and 0.91, respectively. Based on the specificity measure, the FFT outperformed the Hough and wavelet transforms. However, the wavelet transform obtained a higher dice similarity score (DSC) (0.93), accuracy (0.95), and sensitivity metric (0.97) and was the fastest, with an execution time of 0.01 s per frame, making it suitable for real-time applications.
The proposed technique provides an easy-to-implement method for quality reporting or objective comparison tools of different bowel preparation paradigms in real-time applications due to its fast execution time. The obtained results from two different datasets proved that the presented method has good generalization. |
---|---|
ISSN: | 2352-9148 2352-9148 |
DOI: | 10.1016/j.imu.2023.101364 |