Use of multimodal dataset in AI for detecting glaucoma based on fundus photographs assessed with OCT: focus group study on high prevalence of myopia

Glaucoma is one of the major causes of blindness; it is estimated that over 110 million people will be affected by glaucoma worldwide by 2040. Research on glaucoma detection using deep learning technology has been increasing, but the diagnosis of glaucoma in a large population with high incidence of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC medical imaging 2022-11, Vol.22 (1), p.206-206, Article 206
Hauptverfasser: Lim, Wee Shin, Ho, Heng-Yen, Ho, Heng-Chen, Chen, Yan-Wu, Lee, Chih-Kuo, Chen, Pao-Ju, Lai, Feipei, Jang, Jyh-Shing Roger, Ko, Mei-Lan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Glaucoma is one of the major causes of blindness; it is estimated that over 110 million people will be affected by glaucoma worldwide by 2040. Research on glaucoma detection using deep learning technology has been increasing, but the diagnosis of glaucoma in a large population with high incidence of myopia remains a challenge. This study aimed to provide a decision support system for the automatic detection of glaucoma using fundus images, which can be applied for general screening, especially in areas of high incidence of myopia. A total of 1,155 fundus images were acquired from 667 individuals with a mean axial length of 25.60 ± 2.0 mm at the National Taiwan University Hospital, Hsinchu Br. These images were graded based on the findings of complete ophthalmology examinations, visual field test, and optical coherence tomography into three groups: normal (N, n = 596), pre-perimetric glaucoma (PPG, n = 66), and glaucoma (G, n = 493), and divided into a training-validation (N: 476, PPG: 55, G: 373) and test (N: 120, PPG: 11, G: 120) sets. A multimodal model with the Xception model as image feature extraction and machine learning algorithms [random forest (RF), support vector machine (SVM), dense neural network (DNN), and others] was applied. The Xception model classified the N, PPG, and G groups with 93.9% of the micro-average area under the receiver operating characteristic curve (AUROC) with tenfold cross-validation. Although normal and glaucoma sensitivity can reach 93.51% and 86.13% respectively, the PPG sensitivity was only 30.27%. The AUROC increased to 96.4% in the N + PPG and G groups. The multimodal model with the N + PPG and G groups showed that the AUROCs of RF, SVM, and DNN were 99.56%, 99.59%, and 99.10%, respectively; The N and PPG + G groups had less than 1% difference. The test set showed an overall 3%-5% less AUROC than the validation results. The multimodal model had good AUROC while detecting glaucoma in a population with high incidence of myopia. The model shows the potential for general automatic screening and telemedicine, especially in Asia. The study was approved by the Institutional Review Board of the National Taiwan University Hospital, Hsinchu Branch (no. NTUHHCB 108-025-E).
ISSN:1471-2342
1471-2342
DOI:10.1186/s12880-022-00933-z