Spectral Characteristics of the Double-Folded Slot Antennas with Cold-Electron Bolometers for the 220/240 GHz Channels of the LSPE Instrument
We present the results of the experimental and theoretical study of the resonant properties and noise of a single cell of a receiving system based on cold-electron bolometers (CEB) with a double-folded slot antenna and coplanar lines. The system was designed to receive signals at 220/240 GHz frequen...
Gespeichert in:
Veröffentlicht in: | Applied sciences 2021-11, Vol.11 (22), p.10746 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present the results of the experimental and theoretical study of the resonant properties and noise of a single cell of a receiving system based on cold-electron bolometers (CEB) with a double-folded slot antenna and coplanar lines. The system was designed to receive signals at 220/240 GHz frequencies with a 5% bandwidth. In measurements, we used the samples of the double-folded slot antennas with slot lengths of 162 um and coplanar line lengths from 185 to 360 um. Measurements of the resonance properties of CEB located at 0.3 K cryostat plate were carried out using a generator based on a high-temperature YBCO Josephson junction located inside the same cryostat at 4 K plate. This arrangement made it possible to obtain smooth amplitude-frequency characteristics with a clearly defined peak of a 15–21 GHz bandwidth at different frequencies. Based on these results, 2-D array of double-folded slot antennas with CEBs as 220/240 GHz LSPE channel prototype was calculated.The absorption efficiency of the array has reached 81% and 77% for 220 and 240 GHz channels, respectively. |
---|---|
ISSN: | 2076-3417 2076-3417 |
DOI: | 10.3390/app112210746 |