Diagnostic accuracy in axial spondyloarthritis: a systematic evaluation of the role of clinical information in the interpretation of sacroiliac joint imaging

ObjectivesRadiography and MRI of the sacroiliac joints (SIJ) are relevant for the diagnosis and classification of patients with axial spondyloarthritis (axSpA). This study aimed to evaluate the impact of clinical information (CI) on the accuracy of imaging interpretation.MethodsOut of 109 patients r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rheumatic & musculoskeletal diseases open 2024-04, Vol.10 (2), p.e004044
Hauptverfasser: Pohlner, Tim, Deppe, Dominik, Ziegeler, Katharina, Proft, Fabian, Protopopov, Mikhail, Rademacher, Judith, Rios Rodriguez, Valeria, Torgutalp, Murat, Braun, Jürgen, Diekhoff, Torsten, Poddubnyy, Denis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ObjectivesRadiography and MRI of the sacroiliac joints (SIJ) are relevant for the diagnosis and classification of patients with axial spondyloarthritis (axSpA). This study aimed to evaluate the impact of clinical information (CI) on the accuracy of imaging interpretation.MethodsOut of 109 patients referred because of suspicion of axSpA with complete imaging sets (radiographs and MRI of SIJ), 61 were diagnosed with axSpA (56%). Images were independently evaluated by three radiologists in four consecutive reading campaigns: radiographs and radiographs+MRI without and with CI including demographic data, SpA features, physical activity and pregnancy. Radiographs were scored according to the modified New York criteria, and MRIs for inflammatory and structural changes compatible with axSpA (yes/no). The clinical diagnosis was taken as reference standard. The compatibility of imaging findings with a diagnosis of axSpA (precision) before and after the provision of CI and radiologists’ confidence with their findings (0–10) were evaluated.ResultsThe precision of radiographs evaluation without versus with CI increased from 70% to 78% (p=0.008), and for radiographs+MRI from 81% to 82% (p=1.0), respectively. For CR alone, the sensitivity and specificity of radiologic findings were 51% and 94% without and 60% and 100% with CI, while, for radiographs+MRI, they were 74% and 90% vs 71% and 98%, respectively. The diagnostic confidence of radiologists increased from 5.2±1.9 to 6.0±1.7 with CI for radiographs, and from 6.7±1.6 to 7.2±1.6 for radiographs+MRI, respectively.ConclusionThe precision, specificity and diagnostic confidence of radiologic evaluation increased when CI was provided.
ISSN:2056-5933
2056-5933
DOI:10.1136/rmdopen-2023-004044