Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population

Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. This is a retrospective case series. Cataract patients with preoperative binocular measurements were recruited. A binocu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of ophthalmology 2020-10, Vol.2020 (2020), p.1-9
Hauptverfasser: Jing, Qinghe, Chen, Jiahui, Deng, Michael, Chen, Tianhui, Zhang, Min, Jiang, Yongxiang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. This is a retrospective case series. Cataract patients with preoperative binocular measurements were recruited. A binocular axial difference of ≥1 mm was considered to indicate aniso-axial length. The anterior segmental biometrics were measured using Pentacam HR (Oculus, Wetzlar, Germany) and IOLMaster 500 (Carl Zeiss Meditec, Jena, Germany). Comparisons of biometrics were made among 4 eye conditions: the longer eyes from aniso-axial length patients, the shorter eyes from aniso-axial length patients, the longer eyes from non-aniso-axial length patients, and the shorter eyes from non-aniso-axial length patients. The aniso-axial length eyes were also stratified into 8 subgroups with axial length (AL) increments of 1 mm, and the biometrics of the subgroups were compared. Results. There was smaller anterior corneal astigmatism in the shorter aniso-axial length group than those in the longer aniso-axial length group (1.01 ± 0.70 D vs 1.12 ± 0.76 D, P=0.031). The longer aniso-axial length eyes had greater anterior corneal steep curvature (44.13 ± 1.69 D vs 43.87 ± 1.69 D, P=0.009) and anterior corneal astigmatism (1.12 ± 0.76 D vs 1.02 ± 0.69 D, P=0.023) compared with longer non-aniso-axial length subjects. Other corneal biometrics were similar between the aniso-axial length eyes and the non-aniso-axial length eyes. In the longer aniso-axial length group, the posterior corneal aberrations of eyes in the ≥5 mm subgroups were greater than those in the
ISSN:2090-004X
2090-0058
DOI:10.1155/2020/4760978