Application of electrochemical methods for the investigation of intergranular corrosion welded joint austenitic stainless steel 19Cr-9Ni

Sensitization degree of the austenitic stainless steel welded joints was investigated by electrochemical methods of the double loop electrochemical potentiokinetic reactivation (DL EPR) in H2SO4 + KSCN solution, and by the measurement of corrosion potential of the steel in the drop of the solution o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hemijska industrija 2011, Vol.65 (2), p.179-186
Hauptverfasser: Jegdic, Bore, Alil, Ana, Milutinovic, Zlatan, Odanovic, Zoran, Gligorijevic, Bojan, Katavic, Boris
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Sensitization degree of the austenitic stainless steel welded joints was investigated by electrochemical methods of the double loop electrochemical potentiokinetic reactivation (DL EPR) in H2SO4 + KSCN solution, and by the measurement of corrosion potential of the steel in the drop of the solution of HNO3 + FeCl3 + HCl. The welded joints were tested by X-ray radiographic method in order to check the presence of the weld defects. Grain size of the base metal and the welded joints were determined by optical microscopy. Good agreement between the results obtained by different electrochemical methods was obtained. Heat-affected zone (HAZ) of the austenitic stainless steel welded joints has shown significant degree of sensitization. The double loop electrochemical potentiokinetic method gave quantitative evidence about susceptibility of the stainless steel to intergranular corrosion. nema
ISSN:0367-598X
2217-7426
DOI:10.2298/HEMIND101122005J