Application of electrochemical methods for the investigation of intergranular corrosion welded joint austenitic stainless steel 19Cr-9Ni
Sensitization degree of the austenitic stainless steel welded joints was investigated by electrochemical methods of the double loop electrochemical potentiokinetic reactivation (DL EPR) in H2SO4 + KSCN solution, and by the measurement of corrosion potential of the steel in the drop of the solution o...
Gespeichert in:
Veröffentlicht in: | Hemijska industrija 2011, Vol.65 (2), p.179-186 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Sensitization degree of the austenitic stainless steel welded joints was
investigated by electrochemical methods of the double loop electrochemical
potentiokinetic reactivation (DL EPR) in H2SO4 + KSCN solution, and by the
measurement of corrosion potential of the steel in the drop of the solution
of HNO3 + FeCl3 + HCl. The welded joints were tested by X-ray radiographic
method in order to check the presence of the weld defects. Grain size of the
base metal and the welded joints were determined by optical microscopy. Good
agreement between the results obtained by different electrochemical methods
was obtained. Heat-affected zone (HAZ) of the austenitic stainless steel
welded joints has shown significant degree of sensitization. The double loop
electrochemical potentiokinetic method gave quantitative evidence about
susceptibility of the stainless steel to intergranular corrosion.
nema |
---|---|
ISSN: | 0367-598X 2217-7426 |
DOI: | 10.2298/HEMIND101122005J |