Design of 6 switched 3-level inverter with RL load

In this study, an alternative topology to multilevel inverter topologies is given. 6 IGBT seminconductor switches are used in this topology and coupled inductors are used in the output stage of the inverter. Using coupled inductors voltages, the 6 switched 3-level inverter has been obtained. In the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mühendislik bilimleri dergisi 2016-01, Vol.22 (5), p.349-352
Hauptverfasser: Saygın, Ali, Kerem, Alper
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, an alternative topology to multilevel inverter topologies is given. 6 IGBT seminconductor switches are used in this topology and coupled inductors are used in the output stage of the inverter. Using coupled inductors voltages, the 6 switched 3-level inverter has been obtained. In the simulation study, Proportional Integral (PI) controller has been used. By using the data taken from controller, the required switching signals have been produced for a 6 switched 3-level inverter. These signals have been taken by using space vector pulse width modulation technique. Using Computer Aided Design (CAD) analysis a RL load that have 10 Ω and 0.2 H values is simulated and inverter performance has been investigated.