Effect of metal artifact removal modes on the accuracy of linear measurement around titanium implants by applying different voltages: an original article
This study aims to evaluate the effects of the artifact removal algorithm on linear measurements of the buccal cortical plate by altering the voltage. Ten titanium fixtures were inserted at the site of central, lateral, canine, premolars and molars of dry human mandibles. Vertical height of buccal p...
Gespeichert in:
Veröffentlicht in: | BMC medical imaging 2023-06, Vol.23 (1), p.74-74, Article 74 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study aims to evaluate the effects of the artifact removal algorithm on linear measurements of the buccal cortical plate by altering the voltage.
Ten titanium fixtures were inserted at the site of central, lateral, canine, premolars and molars of dry human mandibles. Vertical height of buccal plate was measured using a digital caliper as a gold standard. Mandibles were scanned with 54 and 58 kVp. Other parameters were constant. Images were reconstructed with none, low, medium and high artifact removal modes. Two Oromaxillofacial radiologists evaluated and measured the buccal plate height using Romexis software. Statistical package for the social sciences (SPSS) version 24 was used for data analysis.
In medium and high modes, the difference between 54 and 58 kVp was significant (p |
---|---|
ISSN: | 1471-2342 1471-2342 |
DOI: | 10.1186/s12880-023-01025-2 |