Assessment of the Performance of Lactate Dehydrogenase-Based Rapid Diagnostic Test for Malaria in Djibouti in 2022-2023
Until 2020, Djiboutian health authorities relied on histidine-rich protein-2 (HRP2)-based rapid diagnostic tests (RDTs) to establish the diagnosis of . The rapid spread of histidine-rich protein-2 and -3 ( ) gene-deleted parasite strains in Djibouti has led the authorities to switch from HRP2-based...
Gespeichert in:
Veröffentlicht in: | Diagnostics (Basel) 2024-01, Vol.14 (3), p.262 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Until 2020, Djiboutian health authorities relied on histidine-rich protein-2 (HRP2)-based rapid diagnostic tests (RDTs) to establish the diagnosis of
. The rapid spread of
histidine-rich protein-2 and -3 (
) gene-deleted parasite strains in Djibouti has led the authorities to switch from HRP2-based RDTs to lactate dehydrogenase (LDH)-based RDTs targeting the plasmodial lactate dehydrogenase (pLDH) specific for
and
(RapiGEN BIOCREDIT Malaria Ag Pf/Pv pLDH/pLDH) in 2021. This study was conducted with the primary objective of evaluating the diagnostic performance of this alternative RDT. Operational constraints related, in particular, to the implementation of this RDT during the COVID-19 pandemic were also considered. The performance of BIOCREDIT Malaria Ag Pf/Pv (pLDH/pLDH) RDT was also compared to our previously published data on the performance of two HRP2-based RDTs deployed in Djibouti in 2018-2020. The diagnosis of 350 febrile patients with suspected malaria in Djibouti city was established using two batches of RapiGEN BIOCREDIT Malaria Ag Pf/Pv (pLDH/pLDH) RDT over a two-year period (2022 and 2023) and confirmed by real-time quantitative polymerase chain reaction. The sensitivity and specificity for the detection of
were 88.2% and 100%, respectively. For
, the sensitivity was 86.7% and the specificity was 100%. Re-training and closer supervision of the technicians between 2022 and 2023 have led to an increased sensitivity to detect
(69.8% in 2022 versus 88.2% in 2023;
< 0.01). The receiver operating characteristic curve analysis highlighted a better performance in the diagnosis of
with pLDH-based RDTs compared with previous HRP2-based RDTs. In Djibouti, where
-deleted strains are rapidly gaining ground, LDH-based RDTs seem to be more suitable for diagnosing
than HRP2-based RDTs. Awareness-raising and training for technical staff have also been beneficial. |
---|---|
ISSN: | 2075-4418 2075-4418 |