Are cause of death data for Shanghai fit for purpose? A retrospective study of medical records

ObjectivesTo assess the quality of cause of death reporting in Shanghai for both hospital and home deaths.Design and settingMedical records review (MRR) to independently establish a reference data set against which to compare original and adjusted diagnoses from a sample of three tertiary hospitals,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMJ open 2022-02, Vol.12 (2), p.e046185-e046185
Hauptverfasser: Chen, Lei, Xia, Tian, Yuan, Zheng-An, Rampatige, Rasika, Chen, Jun, Li, Hang, Adair, Timothy, Yu, Hui-Ting, Bratschi, Martin, Setel, Philip, Rajasekhar, Megha, Chowdhury, H R, Gamage, Saman Hattotuwa, Fang, Bo, Azam, Omair, Santon, Romain, Gu, Zhen, Tan, Ziwen, Wang, Chunfang, Lopez, Alan D, Wu, Fan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ObjectivesTo assess the quality of cause of death reporting in Shanghai for both hospital and home deaths.Design and settingMedical records review (MRR) to independently establish a reference data set against which to compare original and adjusted diagnoses from a sample of three tertiary hospitals, one secondary level hospital and nine community health centres in Shanghai.Participants1757 medical records (61% males, 39% females) of deaths that occurred in these sample sites in 2017 were reviewed using established diagnostic standards.InterventionsNone.Primary outcomeOriginal underlying cause of death (UCOD) from medical facilities.Secondary outcomeRoutine UCOD assigned from the Shanghai Civil Registration and Vital Statistics (CRVS) system and MRR UCODs from MRR.ResultsThe original UCODs as assigned by doctors in the study facilities were of relatively low quality, reduced to 31% of deaths assigned to garbage codes, reduced to 2.3% following data quality and follow back procedures routinely applied by the Shanghai CRVS system. The original UCOD had lower chance-corrected concordance and cause-specific mortality fraction accuracy of 0.57 (0.44, 0.70) and 0.66, respectively, compared with 0.75 (0.66, 0.85) and 0.96, respectively, after routine data checking procedures had been applied.ConclusionsTraining in correct death certification for clinical doctors, especially tertiary hospital doctors, is essential to improve UCOD quality in Shanghai. A routine quality control system should be established to actively track diagnostic performance and provide feedback to individual doctors or facilities as needed.
ISSN:2044-6055
2044-6055
DOI:10.1136/bmjopen-2020-046185