Diagnostic value of high-resolution ultrasound combined with multi-slice computer tomography (MSCT) for pediatric intra-abdominal hernias: a retrospective study
To explore the diagnostic value of high-resolution ultrasound combined with multi-slice computer tomography (MSCT) for pediatric intra-abdominal hernias (IAHs), and to analyze the potential causes for missed diagnosis and misdiagnosis of IAHs in children. A retrospective analysis was conducted on 45...
Gespeichert in:
Veröffentlicht in: | BMC surgery 2024-06, Vol.24 (1), p.190-10 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To explore the diagnostic value of high-resolution ultrasound combined with multi-slice computer tomography (MSCT) for pediatric intra-abdominal hernias (IAHs), and to analyze the potential causes for missed diagnosis and misdiagnosis of IAHs in children.
A retrospective analysis was conducted on 45 children with surgically confirmed IAHs. The diagnostic rate of IAHs by preoperative high-resolution ultrasound combined with MSCT was compared with that of intraoperative examination, and the potential causes for missed diagnosis and misdiagnosis by the combination method were analyzed.
Forty-five cases of pediatric IAHs were categorized into primary (25/45, 55.5%) and acquired secondary hernias (20/45, 44.5%). Among children with primary hernias, mesenteric defects were identified as the predominant subtype (40%). Acquired secondary hernias typically resulted from abnormal openings in the abdominal wall or band adhesions due to trauma, surgery, or inflammation. In particular, adhesive band hernias were the major type in children with acquired secondary hernias (40%). The diagnostic rate of high-resolution ultrasound was 77.8%, with "cross sign" as a characteristic ultrasonic feature. Among 10 cases of missed diagnosis or misdiagnosis, 5 were finally diagnosed as IAHs by multi-slice computer tomography (MSCT). Overall, the diagnostic rate of pediatric IAHs by preoperative ultrasound combined with radiological imaging reached 88.9%.
IAHs in children, particularly mesenteric defects, are prone to strangulated intestinal obstruction and necrosis. High-resolution ultrasound combined with MSCT greatly enhances the diagnostic accuracy of pediatric IAHs. |
---|---|