Quartz-Enhanced Photoacoustic Spectroscopy Assisted by Partial Least-Squares Regression for Multi-Gas Measurements
We report on the use of quartz-enhanced photoacoustic spectroscopy (QEPAS) for multi-gas detection. Photoacoustic (PA) spectra of mixtures of water (H2O), ammonia (NH3), and methane (CH4) were measured in the mid-infrared (MIR) wavelength range using a mid-infrared (MIR) optical parametric oscillato...
Gespeichert in:
Veröffentlicht in: | Sensors (Basel, Switzerland) Switzerland), 2023-09, Vol.23 (18), p.7984 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report on the use of quartz-enhanced photoacoustic spectroscopy (QEPAS) for multi-gas detection. Photoacoustic (PA) spectra of mixtures of water (H2O), ammonia (NH3), and methane (CH4) were measured in the mid-infrared (MIR) wavelength range using a mid-infrared (MIR) optical parametric oscillator (OPO) light source. Highly overlapping absorption spectra are a common challenge for gas spectroscopy. To mitigate this, we used a partial least-squares regression (PLS) method to estimate the mixing ratio and concentrations of the individual gasses. The concentration range explored in the analysis varies from a few parts per million (ppm) to thousands of ppm. Spectra obtained from HITRAN and experimental single-molecule reference spectra of each of the molecular species were acquired and used as training data sets. These spectra were used to generate simulated spectra of the gas mixtures (linear combinations of the reference spectra). Here, in this proof-of-concept experiment, we demonstrate that after an absolute calibration of the QEPAS cell, the PLS analyses could be used to determine concentrations of single molecular species with a relative accuracy within a few % for mixtures of H2O, NH3, and CH4 and with an absolute sensitivity of approximately 300 (±50) ppm/V, 50 (±5) ppm/V, and 5 (±2) ppm/V for water, ammonia, and methane, respectively. This demonstrates that QEPAS assisted by PLS is a powerful approach to estimate concentrations of individual gas components with considerable spectral overlap, which is a typical scenario for real-life adoptions and applications. |
---|---|
ISSN: | 1424-8220 1424-8220 |
DOI: | 10.3390/s23187984 |