X-ray computed tomography for predictive quality assessment, 3D visualisation of micro-injection mouldings and soft-tool deformation

[Display omitted] •X-ray computed tomography (XCT) is demonstrated for quality inspection of micro-injection mouldings and soft-tool deformation.•XCT results compared against laser-scanning confocal microscopy.•The approach provided an in-line quality predictive model up to 92% accuracy for filling...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Materials & design 2023-03, Vol.227, p.111741, Article 111741
Hauptverfasser: Gülçür, Mert, Wilson, Paul, Donnelly, Michael, Couling, Kevin, Goodship, Vannessa, Charmet, Jérôme, Williams, Mark A., Gibbons, Gregory
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •X-ray computed tomography (XCT) is demonstrated for quality inspection of micro-injection mouldings and soft-tool deformation.•XCT results compared against laser-scanning confocal microscopy.•The approach provided an in-line quality predictive model up to 92% accuracy for filling prediction. This work presents X-ray computed tomography (XCT) as a dimensional quality assurance technique for micro-injection moulded polymeric test objects for the establishment of predictive quality models and quantifying soft-tool deformation. The results are compared against an industry standard laser-scanning-confocal microscope (LSCM) for the evaluation of XCT’s capability. The work demonstrates; (i) the exploitation of a XCT equipment for dimensional characterisation of micro-injection moulded products made out of polymers with adequate acquisition times, (ii) that acquired XCT data from the 3D visualisation of the micromouldings perform on par with a laser-scanning-confocal microscope in a quality prediction model, (iii) that the deformation occurring in an additively manufactured soft-tool can be quantified using XCT. The technique was particularly superior in volumetric data acquisition compared to LSCM in the filling prediction of the micromouldings. Better accuracy and repeatability in predicting the quality of the mouldings up to 92% achieved with XCT, in conjunction with an in-line collected soft-tool surface temperature data as an indirect quality assurance method. Given the capability of the XCT for the 3D data acquisition of polymeric miniature components, the approach described here has great potential in high-value micro-manufacturing process quality modelling for in-line quality assessment of miniature and added value products in data-rich contexts. Rendered 3D animation of the X-ray CT data: https://youtu.be/KwZty_yoDfs.
ISSN:0264-1275
DOI:10.1016/j.matdes.2023.111741