Bimetallic ammeter: a novel method of current measurement

An electric current flowing through a bimetallic coil heats it up, and due to thermal expansion, the coil either unwinds or winds depending on the direction of net heat transfer and the specific heat capacities of the metals used. This means that by relating a certain measure of its mechanical displ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Emergent scientist 2020, Vol.4, p.2
Hauptverfasser: Uy, Robert Frederik, Miao, Qiaozi, Yuan, Chenghao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An electric current flowing through a bimetallic coil heats it up, and due to thermal expansion, the coil either unwinds or winds depending on the direction of net heat transfer and the specific heat capacities of the metals used. This means that by relating a certain measure of its mechanical displacement with current, the bimetallic coil can be used as an ammeter. Thus, a mathematical model relating the current to the time taken by the bimetallic coil to unwind a fixed displacement was developed and verified through experiments, which show a good agreement between theoretical and experimental values.