Performance Analysis and Optimization for Static Mixer of SCR Denitration System under Different Arrangements
In order to solve the poor flow performance issues of selective catalytic reduction (SCR) denitration systems, the effect of the static mixer on the flow field was studied using computational fluid dynamics (CFD) numerical simulations. Based on the analysis of the original SCR denitration system, tw...
Gespeichert in:
Veröffentlicht in: | Energies (Basel) 2022-12, Vol.15 (23), p.8977 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In order to solve the poor flow performance issues of selective catalytic reduction (SCR) denitration systems, the effect of the static mixer on the flow field was studied using computational fluid dynamics (CFD) numerical simulations. Based on the analysis of the original SCR denitration system, two static mixers were selected to explore their influence on system performance. The results show that both static mixers can effectively improve the denitration performance under different conditions. The static mixer with a rotating arrangement showed a better performance in the uniformity of concentration. The pressure loss without a static mixer is 834 Pa, and the pressure loss increases by 94 Pa and 73 Pa for rotating and X-arranged static mixers, respectively. Meanwhile, a static mixer will increase energy loss. Therefore, power plants can choose the layout of their static mixers according to the actual situation to achieve the optimal performance. |
---|---|
ISSN: | 1996-1073 1996-1073 |
DOI: | 10.3390/en15238977 |