Transcatheter Aortic Valve-in-Valve Implantation Complicated by Aorto-Right Ventricular Fistula

We describe the case of a degenerative, sutureless bioprosthetic valve (BPV) with deformation and stent infolding in a patient with elevated surgical risk. Following discussion among the heart team, balloon valve fracture was performed to facilitate deployment of an aortic valve-in-valve transcathet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Case reports 2020-02, Vol.2 (2), p.309-311
Hauptverfasser: Patterson, Tiffany, Rajani, Ronak, Esposito, Giulia, Allen, Christopher, Adams, Heath, Prendergast, Bernard, Young, Christopher, Redwood, Simon
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe the case of a degenerative, sutureless bioprosthetic valve (BPV) with deformation and stent infolding in a patient with elevated surgical risk. Following discussion among the heart team, balloon valve fracture was performed to facilitate deployment of an aortic valve-in-valve transcatheter heart valve. Post-procedural imaging demonstrated BPV frame protrusion and contained annular rupture, which required operative intervention. (Level of Difficulty: Intermediate.) [Display omitted] This paper describes the case of a degenerative, sutureless bioprosthetic valve (BPV) with deformation and stent infolding in a patient with elevated…