Pesticide wastewater treatment by combination process of air flotation/iron-carbon /Fenton+ hydrolytic acidification+A/O+ contact oxidation

A combined process of air flotation/iron carbon microelectrolysis /Fenton+ hydrolytic acidification +A/O+ contact oxidation is used to treat pesticide wastewater . The results show that,when the influent COD,NH3-N and toluene concentrations are 7 866,56 and 53 mg/L,the treated effluent COD,NH3-N and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gong ye shui chu li 2024-02, Vol.44 (2), p.190-193
Hauptverfasser: TIAN Qiping, XU Meng, LAI Liang, XU Liya, Zhang Feng, YAO Huaqi
Format: Artikel
Sprache:chi
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A combined process of air flotation/iron carbon microelectrolysis /Fenton+ hydrolytic acidification +A/O+ contact oxidation is used to treat pesticide wastewater . The results show that,when the influent COD,NH3-N and toluene concentrations are 7 866,56 and 53 mg/L,the treated effluent COD,NH3-N and toluene concentrations are 435,13 and 0.4 mg/L,respectively. The average removal rates of COD,NH3-N and toluene were 94.5%,81% and 99.2%,respectively. The drainage index reached the Class B standard of Quality Standard for Sewage Discharge into Urban Sewers (GB/T 31962—2015),and the process efficiency was reliable,which can provide reference for the design and construction of similar pesticide wastewater treatment.
ISSN:1005-829X
DOI:10.19965/j.cnki.iwt.2023-0199