Comparison of Predictability Using Barrett Universal II and SRK/T Formulas according to Keratometry
Purpose. To compare the predictability of intraocular lens (IOL) power calculation using the Barrett Universal II and the SRK/T formulas, according to the keratometry. Methods. We retrospectively reviewed the clinical charts of 335 consecutive eyes undergoing standard cataract surgery. IOL power cal...
Gespeichert in:
Veröffentlicht in: | Journal of ophthalmology 2020, Vol.2020 (2020), p.1-5 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose. To compare the predictability of intraocular lens (IOL) power calculation using the Barrett Universal II and the SRK/T formulas, according to the keratometry. Methods. We retrospectively reviewed the clinical charts of 335 consecutive eyes undergoing standard cataract surgery. IOL power calculations were performed using the Barrett Universal II and the SRK/T formulas. We compared the prediction error, the absolute error, and the percentages within ±0.25, ±0.5, and ±1.0 D of the targeted refraction, 1 month postoperatively, and also investigated the relationship of these outcomes with the keratometric readings, using the two formulas. Results. The prediction error using the SRK/T formula was significantly more myopic than that using the Barrett Universal II formula (the paired t-test, p |
---|---|
ISSN: | 2090-004X 2090-0058 |
DOI: | 10.1155/2020/7625725 |