To evaluate chest computed tomography (CT) compared to intracavitary electrocardiogram (ECG) in predicting the length of peripherally inserted central catheter (PICC) placement and analyzing the accuracy of the positioning methods. This study included a total number of 436 patients who underwent PIC...
Gespeichert in:
Veröffentlicht in: | BMC surgery 2022-05, Vol.22 (1), p.197-197, Article 197 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To evaluate chest computed tomography (CT) compared to intracavitary electrocardiogram (ECG) in predicting the length of peripherally inserted central catheter (PICC) placement and analyzing the accuracy of the positioning methods.
This study included a total number of 436 patients who underwent PICC placement. The patients enrolled were randomly divided into two groups: ECG group (n = 218, received IC-ECG) and chest CT group (n = 218, received chest CT). The tip length of the catheter in the superior vena cava, the measured length of the catheter and the actual insertion length of the catheter were observed and recorded in the two groups.
The best catheterization rate of tip positioning and the one-time placement rate of tip positioning in ECG group were significantly higher than that in the chest CT group (all P |
---|---|