Kinetic and equilibrium study of graphene and copper oxides modified nanocomposites for metal ions adsorption from binary metal aqueous solution

Presently, the main cause of pollution of natural water resources is heavy metal ions. The removal of metal ions such as nickel (Ni ) and cadmium (Cd ) has been given considerable attention due to their health and environmental risks. In this regard, for wastewater treatment containing heavy metal i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Frontiers in chemistry 2023-11, Vol.11, p.1279948
Hauptverfasser: Ali, Alaa H, Kareem, Asmaa Bahjat, Al-Rawi, Usama A, Khalid, Ushna, Zhang, Shengfu, Zafar, Fatima, Papraćanin, Edisa, Hatshan, Mohammad Rafe, Sher, Farooq
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Presently, the main cause of pollution of natural water resources is heavy metal ions. The removal of metal ions such as nickel (Ni ) and cadmium (Cd ) has been given considerable attention due to their health and environmental risks. In this regard, for wastewater treatment containing heavy metal ions, graphene oxide (GO) nanocomposites with metal oxide nanoparticles (NPs) attained significant importance. In this study, graphene oxide stacked with copper oxide nanocomposites (GO/CuO-NCs) were synthesized and characterized by Fourier transform infrared (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), and atomic force microscopy (AFM) analytical procedures. The prepared GO/CuO-NCs were applied for the removal of Ni and Cd ions from a binary metal ion system in batch and continuous experiments. The obtained results revealed that GO/CuO-NCs exhibited the highest removal efficiencies of Ni (89.60% ± 2.12%) and Cd (97.10% ± 1.91%) at the optimum values of pH: 8, dose: 0.25 g, contact time: 60 min, and at 50 ppm initial metal ion concentration in a batch study. However, 4 mL/min flow rate, 50 ppm initial concentration, and 2 cm bed height were proved to be the suitable conditions for metal ion adsorption in the column study. The kinetic adsorption data exhibited the best fitting with the pseudo-second-order model. The adsorption isotherm provided the best-fitting data in the Langmuir isotherm model. This study suggested that the GO/CuO nanocomposites have proved to be efficient adsorbents for Ni and Cd ions from a binary metal system.
ISSN:2296-2646
2296-2646
DOI:10.3389/fchem.2023.1279948