Determination and pharmacokinetics study of UK-5099 in mouse plasma by LC-MS/MS
UK-5099 is a potent mitochondrial acetone carrier inhibitor, that exhibits anticancer activity. Recently, the anti-Toxoplasma gondii activity of UK-5099 was proposed, and in vivo studies of its pharmacokinetics in BALB/c mice are necessary to further evaluate the clinical effect of UK-5099. A simple...
Gespeichert in:
Veröffentlicht in: | BMC veterinary research 2022-04, Vol.18 (1), p.145-145, Article 145 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | UK-5099 is a potent mitochondrial acetone carrier inhibitor, that exhibits anticancer activity. Recently, the anti-Toxoplasma gondii activity of UK-5099 was proposed, and in vivo studies of its pharmacokinetics in BALB/c mice are necessary to further evaluate the clinical effect of UK-5099.
A simple and fast high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis method was established and verified in terms of its linearity, matrix effect, accuracy, precision, recovery and stability. The analytes were separated by an Agilent ZORBAX XDB-C18 column (2.1 × 50 mm, 3.5 μm) at 30 °C. A gradient mobile phase consisting of water with 0.1% formic acid (FA) (phase A) and acetonitrile (ACN) (phase B) was delivered at a flow rate of 0.40 mL·min
with an injection volume of 5 μL. A good linear response was obtained in a concentration range of 5-5000 ng·mL
(r
= 0.9947). The lower limit of quantification (LLOQ) was 5 ng·mL
. The extraction recovery of UK-5099 was greater than 95%. The inter- and intra-day accuracy and precision of the method showed relative standard deviations (RSDs) of less than 15%. This method has been successfully applied to the pharmacokinetic evaluation of UK-5099 in mouse plasma. In health mice, the main pharmacokinetic parameters of UK-5099 after intraperitoneal administration were measured using a noncompartmental model, in which the AUC
was 42,103 ± 12,072 ng·h·mL
and the MRT
was 0.857 ± 0.143 h. The peak concentration (C
) was 82,500 ± 20,745 ng·h·mL
, which occurred at a peak time (T
) = 0.250 ± 0.000 h.
A fast and sensitive HPLC-MS/MS method was developed, validated and successfully used for the determination of UK-5099 levels in mice after intraperitoneal administration. This study was the first report of the pharmacokinetic parameters of UK-5099 in mice, which will help to further study the administration of UK-5099 in animals and humans. |
---|---|
ISSN: | 1746-6148 1746-6148 |
DOI: | 10.1186/s12917-022-03245-0 |