Stripping voltammetric determination of cadmium and lead ions based on a bismuth oxide surface-decorated nanoporous bismuth electrode

•An effective electrode material Bi2O3@NPBi was prepared by a dealloying method.•A Bi2O3@NPBi electrochemical sensor was developed for detecting heavy metal ions.•The LOD of Pb2+ and Cd2+ detected by Bi2O3@NPBi sensor is lower than other Bi-based sensors. Ultrasensitive detection of heavy metal ions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrochemistry communications 2022-03, Vol.136, p.107233, Article 107233
Hauptverfasser: Wang, Yue, Wu, Xuan, Sun, Jianfeng, Wang, Caiyun, Zhu, Guoyuan, Bai, Li-Ping, Jiang, Zhi-Hong, Zhang, Wei
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•An effective electrode material Bi2O3@NPBi was prepared by a dealloying method.•A Bi2O3@NPBi electrochemical sensor was developed for detecting heavy metal ions.•The LOD of Pb2+ and Cd2+ detected by Bi2O3@NPBi sensor is lower than other Bi-based sensors. Ultrasensitive detection of heavy metal ions through electrochemical methods is a longstanding research topic. One of the most compelling subjects is preparation of modified electrodes with a high specific surface area as well as fast response characteristics. In this study, novel bismuth oxide surface-decorated nanoporous bismuth (Bi2O3@NPBi) was prepared through a typical dealloying method, where a bicontinuous ligament–channel structure greatly improved the electrically active surface area and electron conduction. The Bi2O3@NPBi-modified electrode was employed to detect heavy metal ions using square wave anodic stripping voltammetry (SWASV), and the corresponding limits of detection (LOD) were 0.02 and 0.03 µg/L for simultaneous detection of Pb2+ and Cd2+. Due to the high cycling stability and capacity of bismuth oxides, the relative standard deviation (RSD) of the response currents using Bi2O3@NPBi was less than 4.16%, which is very considerably lower than the RSD of NPBi. Furthermore, a Bi2O3@NPBi-modified electrode was used to determine the concentration of Pb2+ and Cd2+ in tap water samples, and excellent recovery figures were obtained as there is little interference from other co-existing ions. In conclusion, the Bi2O3@NPBi-modified electrode showed good reusability and feasibility for quality assurance in agricultural, food and environmental applications.
ISSN:1388-2481