Reciproc versus Twisted file for root canal filling removal: assessment of apically extruded debris
The aim of this study was to evaluate the amount of apically extruded debris during endodontic retreatment with different file systems. Sixty extracted human mandibular premolar teeth were used in this study. Root canals of the teeth were instrumented and filled before being randomly assigned to thr...
Gespeichert in:
Veröffentlicht in: | European oral research 2016-01, Vol.50 (2), p.31-37 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to evaluate the amount of apically extruded debris during endodontic retreatment with different file systems.
Sixty extracted human mandibular premolar teeth were used in this study. Root canals of the teeth were instrumented and filled before being randomly assigned to three groups. Guttapercha was removed using the Reciproc system, the Twisted File system (TF), and Hedström-files (H-file). Apically extruded debris was collected and dried in pre-weighed Eppendorf tubes. The amount of extruded debris was assessed with an electronic balance. Data were statistically analyzed using one-way ANOVA, Kruskal-Wallis, and Mann-Whitney U tests.
The Reciproc and TF systems extruded significantly less debris than the H-file (p |
---|---|
ISSN: | 2149-2352 2630-6158 2149-4592 2651-2823 |
DOI: | 10.17096/jiufd.96734 |