Simulation of conditions for external and internal exposure of human blood to low doses of 137Cs radionuclide in vitro to study its genotoxicity

Proposed are the models for external exposure to and contamination with 137Cs (imitation of internal exposure) of human blood samples in vitro in doses up to 0.53 Gy for 1.75 h. Exposure conditions and experimental devices, as well as models for the calculation of the absorbed doses under external i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:I͡A︡derna fizyka ta enerhetyka 2020-06, Vol.21 (2), p.166-171
Hauptverfasser: Bezdrobna, L.K., Strilchuk, M.V., Kurochkina, V.A., Fedorchenko, V.I., Khomych, I.A., Tsyganok, T.V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Proposed are the models for external exposure to and contamination with 137Cs (imitation of internal exposure) of human blood samples in vitro in doses up to 0.53 Gy for 1.75 h. Exposure conditions and experimental devices, as well as models for the calculation of the absorbed doses under external irradiation and estimation of the activity of the radioisotope needed to obtain the desired absorbed dose under internal exposure of blood cells, are presented. The created experimental models allow conduction of comparative in vitro studies of the 137Cs genotoxicity at external and internal exposure of human blood.
ISSN:1818-331X
2074-0565
DOI:10.15407/jnpae2020.02.166